PRODUCT
AXS-55
X-ray system built on a CNT cold-cathode C-beam module
The AXS-55 is an X-ray system made up of a carbon nanotube (CNT) cold-cathode C-beam module, a transmission anode and a beryllium (Be) window. It forms the electron beam with an electric field alone, without heating a filament, so it emits X-rays instantly with no warm-up.
Key features
- CNT cold-cathode C-beam module (cathode, gate, focuser)
- 5 × 5 multi-beam array
- Transmission anode and Be window
- Vacuum pumping, power and gauge control in one frame
Details
C-beam module
The electron source of the AXS-55 is a CNT cold-cathode C-beam module. Three electrodes, the cathode, gate and focuser, are stacked on ceramic holders and fastened with M2 nuts and washers.
The focuser electrode and focuser ceramic have an alignment key, so the electrodes line up as the module is assembled.
A 32 mm beam module
The assembled beam module measures 32 mm × 6 mm. With no filament or heater, the electron source can be made small and thin.
5 × 5 multi-beam
Electron beams emerge through the window of the gate electrode in a 5 × 5 array, 25 beams in total.
Separate electrode connectors
Inside the vacuum chamber, the cathode, gate and focuser are each wired through their own connector.
Transmission anode and Be window
The electron beam strikes a transmission anode to generate X-rays, which exit through a beryllium (Be) window. The beam module, anode and Be window are aligned on a single axis.
System layout
The X-ray chamber, vacuum pumping line, power and vacuum valve switches, and the turbomolecular pump (TMP) and vacuum gauge controller are housed in a single frame.
Applications
We are developing it for fields that need compact, fast X-ray sources, such as medical imaging, non-destructive testing and in-line inspection for semiconductor packaging.
Specifications
| Electron source | CNT cold-cathode field emission |
|---|---|
| Electrodes | Cathode, gate, focuser |
| Beam array | 5 × 5 (25 beams) |
| Beam module size | 32 mm × 6 mm |
| Anode | Transmission type |
| X-ray window | Beryllium (Be) |
Specifications are subject to change without notice for improvement.